beautypg.com

Installation – Magnum Energy Series Stacking Cable Kit (ME-SSI) User Manual

Page 10

background image

©

2010 Magnum Energy, Inc.

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

This battery bank uses two battery strings . They must

be connected together in parallel to provide a single

battery bank to the inverters .

DC Negative

Interconnect

(from ME-SSI kit)

DC disconnects and

overcurrent protection

MS4024

L2

inverter

MS4024

L1

inverter

This diagram is for a 24 VDC

battery system. Ensure your

battery bank is wired correctly .

Stacker cable

(from ME-SSI kit)

Figure 4, DC Wiring Using Two Battery Cable Pairs

DC Wiring Using Two Battery Cable Pairs – Each inverter

has its own battery cable pair (positive and negative for each

inverter) connected to the battery bank. There are two DC discon-

nect/overcurrent devices, one for each positive battery cable. Use

only the DC negative interconnect cables from the ME-SSI kit be-

tween the two inverters in this confi guration. The positive intercon-

nect cable is not used in this installation as it may not meet electri-

cal code requirements, and would cause performance issues if only

one DC disconnect/overcurrent device inadvertently opens.

Installation

5