29
© 2010 Magnum Energy, Inc.
Using the ME-RTR Router with the BMK
When using the charge effi ciency’s Auto setting, the AH I/O value is recal-
culated after the battery has been fully charged (reaching 100% SOC) and
≥0.5% of the battery capacity has been discharged. If the Sense Module is
disconnected from power, the displayed AH I/O value resets to zero.
Info: The AH I/O display correlates with the 05B AmpHrs Size setting
(under SETUP button) to help determine the 04A SOC display.AH
I/O example – if you run a 10 amp load for three hours, the display
will show -30 AH. When you begin charging, the display will count
from -30 AH back toward 0 AH.
04E Resetable AHrs –This meter displays the total amp-hours removed
from the battery since it was last reset. This display can be used as a battery
load indicator to help identify and monitor the battery load consumption. The
range is 0 to 65,535.0 amp-hours (0.1 amp-hour resolution).
To reset the AmpHrs value to zero, press and hold the rotary SELECT knob for
>5 seconds when this display is shown. After this display has been reset, it will
begin calculating and displaying new rAH Out values. This display automatically
resets to zero if the Sense Module is disconnected from power.
04F Total kAHrs Out – This meter displays the total amp-hours removed
from the battery since the Sense Module was fi rst connected. This display can
be used as a battery service life indicator. The value is displayed in 0.1k [or
100 amp-hours (“k” equals 1000)] resolution up to a maximum of 6,553.5k
amp-hours (6,553,500 amp-hours). The displayed number resets to 0.0k when
the Sense Module is disconnected from power.
04G Minimum VDC – This menu displays the lowest battery voltage since
the last reset. The voltage shown on the display is averaged each sec-
ond, and is helpful when troubleshooting or detecting an over-discharge
condition. To reset this display, press and hold the rotary SELECT knob for 5
seconds while the Minimum VDC display is shown. After this value has been
reset, the display will begin monitoring and showing new minimum DC input
values. If the battery monitor is not connected or not communicating, the
display will show “0.0”.
04H Maximum VDC – This menu displays the highest battery voltage since the
last reset. The voltage shown on the display is averaged each second, and this
allows you to check your charging system (battery charger, charge controller,
etc.) to ensure the charging voltage has been attained. This display is also help-
ful when troubleshooting or detecting if an over-charge condition has occurred.
To reset this display, press and hold the rotary SELECT knob for 5 seconds
while the Maximum VDC display is shown. After this value has been reset, the
display will begin monitoring and showing new maximum DC input values. If
the battery monitor is not connected or not communicating, the display will
show “0.0”.