beautypg.com

3 adjusting the amphr size setting – Magnum Energy Battery Monitor Kit ME-BMK User Manual

Page 21

background image

17

© 2010 Magnum Energy, Inc.

Using the ME-ARC50 Remote with the BMK

4.2 Adjusting the Charge Effi ciency Setting

The Charge Effi ciency setting allows the battery monitor to calculate the battery’s

charge effi ciency. The charge effi ciency can be calculated automatically using the

Auto setting, or can be manually programmed by the user (see Figure 4-2).
The battery monitor is shipped with the charge effi ciency set to Auto. This allows

the battery monitor to automatically calculate variables that affect the charging

effi ciency such as battery type, battery age, and how the batteries are maintained

– which is not always constant. With the Auto setting, the effi ciency is recalculated

each time the batteries reach a 100% state of charge.
This setting can also be manually adjusted from 50% to 97% if the battery’s

charge effi ciency is known. When using a setting other than the Auto setting, the

battery monitor will use the manual setting to calculate the AH I/O display. For

example, if you set the charge effi ciency to 90% and 100 amp-hrs are removed

from the battery, the AH Net display would read 000 only after 111AH have been

returned to the battery.

If the charge effi ciency is manually set and inaccurate, the SOC information will

be more inaccurate with every charge. For this reason, continually monitor the

AH I/O reading under the ME-ARC50 remote’s METER pushbutton.
To access the AH I/O reading: press the METER pushbutton, turn the SELECT

knob until the 04 BMK Meters menu appears, and then press the SELECT

knob. Turn the SELECT knob until the 04E AH In/Out display appears.
After several charge and discharge cycles (below 80% SOC), the AH I/O read-

ing should be slightly positive when the SOC display reads 99%.
To view the SOC display: press the METER pushbutton and turn the SELECT

knob until the 04 BMK Meters menu appears. Press the SELECT knob, and

then turn the SELECT knob until the 04B SOC display appears. If the AH I/O

reading is below 000 (negative number) when the SOC display reads 99%,

then increase the charge effi ciency setting. If you fi nd that the AH I/O reading

is substantially above zero when the SOC display reads 99%, then decrease

the charge effi ciency setting.

4.3 Adjusting the AmpHr Size Setting

It’s important that the AmpHr Size setting is correct or else the calculations used

to determine the battery’s SOC display will be inaccurate.
To adjust the AmpHr Size setting: press the SETUP pushbutton and turn

the SELECT knob until the 05 BMK Setup menu appears. Press the SELECT

knob to display the 05A Charge Eff menu item. Turn the SELECT knob to

display the 05B AmpHour Size menu with the current AmpHrs Size setting

shown. Press the SELECT knob to access the Set AmpHr Size function. Turn

the SELECT knob to adjust the AmpHr Size setting. Press the SELECT knob

to select and save the new setting.

press to

save

SETUP

press

Status…

05 BMK Setup

rotate to

press to select

(press again to adjust)

rotate to

desired

selection:

Set Charge Eff

Auto

Set Charge Eff

60%

Set Charge Eff

50%

Set Charge Eff

97%

.......

Figure 4-2, Adjusting the Charge Efficiency Setting (ME-ARC50)

This manual is related to the following products: