Using the ME-RC50 Remote with the BMK

3.6 ME-RC50 METER Menu Items and Settings for BMK

Press the METER pushbutton on the ME-RC50 to access the different meters

that determine the status of the inverter/charger and battery system.

Figure 3-4, Accessing the METER Menu Items (ME-RC50)

01 INV/CHG Meter – This menu provides the DC voltage and current of the

inverter/charger when inverting or charging. These are not BMK readings.
02 BM: SOC – This display is the best way to monitor the actual state of

the battery. The read only display shows the State Of Charge (SOC) for the

connected battery bank. The SOC represents the condition of the battery as

a percentage of the available capacity left in the battery. The range is 0% to

100%, where 100% represents a fully charged battery and 0% means the

battery is completely discharged.
When the Sense Module is fi rst connected, the batteries will need to be fully

charged (i.e., SOC = 100%) at least once to establish a SOC reference point.

While this reference point is being calculated, the display will show “Think’n”,

to indicate that the SOC reference point is being calculated. After the batter-

ies are fully charged, the display will change from “Think’n” to “100%” and

begin to provide accurate SOC percentage values.

Info: “Think’n” can take up to several days depending on the charge

source and its ability to completely recharge the batteries (e.g., a

small PV array may not be large enough to replace all the amp-hrs

in a reasonable amount of time).

If the Sense Module is disconnected from power, this display resets to “Think’n”

and the batteries will require another full charge before this display begins

providing SOC percentage information.

Info: Try to limit battery discharging to 50% of capacity (keep

battery above 50% SOC). If batteries are allowed to be continually

discharged below 50% SOC, their effective service life will be con-

siderably shorter. This 50% rule has been determined to be the best

compromise between available energy and the maximum number of

discharge cycles a battery can provide.