beautypg.com

Using the me-rc50 remote with the bmk – Magnum Energy Battery Monitor Kit ME-BMK User Manual

Page 18

background image

© 2010 Magnum Energy, Inc.

14

Using the ME-RC50 Remote with the BMK

03 BM: Meters – This menu shows the battery bank’s DC voltage, DC current,

and AH information that has been provided by the battery meter. The values

for these meter displays are updated each second.

DC Volts – This meter displays the real-time battery voltage from

07.00 to 70.00 volts (± 0.02 volts).
DC Amps – This meter displays the real-time charge current (amps into

the battery) or discharge current (amps out of the battery). Charging is

shown as a positive (+) number and discharging is shown as a negative (-)

number. The range is from ±0.1 to 999 amps, with a 1.0% accuracy.
AH I/O (Amp-Hours In/Out) – This meter displays the amp-hours

returned to or removed from the battery. When this value is positive, it

represents amp-hours returned to the battery during any subsequent

charging. A negative value represents amp-hours removed from a full

battery. The range is ±32,768 AH.
When using the charge effi ciency’s Auto setting, the AH I/O value is

recalculated after the battery has been fully charged (reaching 100%

SOC) and ≥0.5% of the battery capacity has been discharged. If the

Sense Module is disconnected from power, the displayed AH I/O value

resets to zero.

Info: The AH I/O display correlates with the battery amp-hours setting

to help determine the 02 BM: SOC display.

Info: AH I/O example; if you run a 10 amp load for three hours, the

display will show -30 AH. When you begin charging, the display will

count from -30 AH back toward 0 AH.

rAH Out (Resettable Amp-Hours Removed) – This meter displays

the total amp-hours removed from the battery since it was last reset.

This display can be used as a battery load indicator to help identify

and monitor the battery load consumption. The range is 0 to 65,535.0

amp-hours (0.1 amp-hour resolution).
To reset the AmpHrs value to zero, press and hold the rotary SELECT

knob for >5 seconds when this display is shown. After this display

has been reset, it will begin calculating and displaying new rAH Out

values. This display automatically resets to zero if the Sense Module is

disconnected from power.
tAH Out (Total Amp-Hours Removed) – This meter displays the total

amp-hours removed from the battery since the Sense Module was fi rst

connected. This display can be used as a battery service life indicator.

The value is displayed in 0.1k [or 100 amp-hours (“k” equals 1000)]

resolution up to a maximum of 6,553.5k amp-hours (6,553,500 amp-

hours). The displayed number resets to 0.0k when the Sense Module is

disconnected from power.