0 installation, 1 installation requirements, Installation – Magnum Energy AGS Stand Alone (ME-AGS-S) User Manual
Page 7

© 2013 Magnum Energy, Inc.
4
2.0 Installation
Installing the ME-AGS-S is a simple process. Before installing, read this entire
section to familiarize yourself with all aspects of the installation; then, you
can thoroughly plan the details to ensure the overall system requirements
are accomplished. To assist you in planning and designing your installation,
review the basic system diagram shown in Figure 2-1.
WARNING: The ME-AGS-S is not an ignition-protection rated device
and should not be installed in any location that requires ignition-
protected equipment. To prevent fi re or explosion, do not install
the Auto Gen Start controller in any area with extremely fl ammable
liquids like gasoline or propane; or, in an area that contains connec-
tions between components of a fuel system.
CAUTION: Installations should be performed by qualifi ed personnel,
such as a licensed or certifi ed electrician. It is the installer’s respon-
sibility to determine which safety codes apply and to ensure that all
applicable installation requirements are followed. Applicable instal-
lation codes vary depending on the specifi c location and application.
CAUTION: Review the “Important Product Safety Information” on
the front inside cover page before any installation.
2.1 Installation
Requirements
Review the following requirements before installing this device:
•
For the AGS to automatically start and stop the generator properly, the
generator must include an electric start and an automatic choke. To
prevent generator damage and obtain reliable operation, use generator
models designed for unattended operation. These models should also
be equipped with remote operation connections and have protective
systems that cause the generator to shut down from low oil pressure,
over-temperature, starter lockout, and over-crank conditions.
• T
he ME-AGS-S controller is connected to the switch by a 25’ communica-
tions cable. Before installing the ME-AGS-S and connecting any wires,
determine: 1) the communications cable route throughout the home or
vehicle/boat from the controller to the switch, 2) the start/stop signal
wire route from the AGS controller to the generator, and 3) the wire route
from the AGS controller to the monitored battery bank.
Info: Two pigtail adapters (ME-PT1 and ME-PT2) are available to
externally enable the ME-AGS-S to automatically turn the genera-
tor on/off through a manually controlled switch or an automatically
controlled switching device. See Appendix A for more information.
•
Always check for existing electrical, plumbing, or other areas of potential
damage BEFORE drilling or cutting into walls.
•
If installing this device in a boat, RV, or truck, ensure the conductors pass-
ing through walls, bulkheads, or other structural members are protected
to minimize insulation damage such as chafi ng—which can be caused by
vibration or constant rubbing.
•
Do not mount the AGS controller in a closed battery compartment or in
an area
where water
or any other liquid can enter the AGS and cause
shorting or corrosion.
•
The AGS should be wired to not interfere with your air conditioner controls
or the manual start/stop switches on your generator.
Installation