Artisan feature commands, Lamp flash, Logitek – Logitek Electronic Systems Artisan User Manual
Page 58

Logitek
Appendix E
Additional Protocol Commands
Artisan Feature Commands
The following Feature Commands use the AE (Set Effects) command to change the function of
certain Artisan features.
TIP:
The following commands can be sent to the Artisan using CommandBuilder’s ASM
command. Some commands also have direct keyword support in
CommandBuilder. See the CommandBuilder Reference Manual for more
information.
To build a command, lookup each byte in order (sequence #) adjusting the values where
applicable. To be a valid command, the number of bytes to follow must be correct. Where a default
value is shown, this is for reference only and these byte values must still be set.
<00> denotes a byte in hex. All decimal values must be converted to hex.
Lamp Flash
Used to flash a lamp in Artisan buttons. (v1.x and later)
Seq
Byte
Description
Notes
1
<02>
Start byte
2
<06>
Bytes to follow
3
Command = Flag
4
Device Number
Device Number of Lamp section of module
5
Bus Number
Bus Number of Lamp (hex)
6
<06>
Type = Set Flash
7
Data = Flash Rate
<02> = Slow
<03> = Medium <05> = Fast
(do not use other values)
8
Data = Flash Times
<00> to
<00> = continuous
The follow example will set a fast flash 255 times on a Narrow Softkey module on CHAN77:
02 06 B1 57 30 06 05 FF
TIP:
Flash Times is supported only in Artisan v2.x firmware.
Logitek Artisan Reference Manual
56