Additional protocol commands, Artisan busses, Bus assignments – Logitek Electronic Systems Artisan User Manual
Page 56: Fader functions, Appendix e additional protocol commands, Logitek

Logitek
Appendix E
Additional Protocol Commands
Appendix E Additional Protocol Commands
This section documents Logitek Protocol commands specific to the Artisan surface. These
commands add additional support for functions such as meter bridge feature locations, timer
controls and advanced feature sets.
The standard set of Logitek Protocol commands (such as channel on; channel off; input route;
fader level; etc, is documented in the Logitek Protocol Reference.)
Artisan Busses
These Bus settings supplement/replace the standard busses available in the Logitek system. Please
note the Artisan uses assignment Busses that differ from Logitek radio consoles.
Bus Assignments
BUS0
On/Off Switch
BUS1
Master 1
BUS2
PFL/CUE
BUS3
Master 2
BUS4
Sub-master 1
BUS5
Sub-master 2
BUS6
Sub-master 3
BUS9
Sub-master 4
BUS10
Sub-master 5
BUS11
Sub-master 6
BUS12
Sub-master 7
BUS13
Sub-master 8
TIP:
Aux Sends are not controlled by Bus Assignments but can be externally controlled
using the Set Effects command documented later in this appendix.
Fader Functions
BUS17
Channel On button lamp address
The above Bus is used to address Artisan Color or Flash commands to the fader ON button. The
lamp state is not addressed by this command; instead it is tied to the channel’s BUS0 state.
BUS37
Select mode for “IN” button – OFF = last input / ON = default input
BUS38
Master 1 bus lock (ON = locked)
BUS39
Master 1 bus lock (ON = locked)
BUS40
Sub-master 1 bus lock (ON = locked)
BUS41
Sub-master 2 bus lock (ON = locked)
BUS42
Sub-master 3 bus lock (ON = locked)
BUS43
Sub-master 4 bus lock (ON = locked)
BUS44
Sub-master 5 bus lock (ON = locked)
BUS45
Sub-master 6 bus lock (ON = locked)
BUS46
Sub-master 7 bus lock (ON = locked)
BUS47
Sub-master 8 bus lock (ON = locked)
Logitek Artisan Reference Manual