PC Health Status

This menu shows the hardware monitor configuration

settings. Select an item then press to display the

configuration options.

SYS/CPU Temperature

The onboard hardware monitor automatically detects and

displays the CPU and motherboard temperatures.

FAN2 Speed (CPU FAN)

The onboard hardware monitor automatically detects and

displays the CPU fan speeds in rotations per minute (RPM).

If the fan is not connected to the motherboard, it displays

N/A.

CPU Voltage, 3.3V voltage, 5V voltage, VBAT, etc

The onboard hardware monitor automatically detects the

voltage output through the onboard voltage regulators.

Smart Fan Mode Configuration

It allows you to configure the smart fan feature. You

can manually turn on the CPU fan or set the target CPU

temperature at which the CPU fan will start running if the

fan is not yet turned on. And the CPU fan can also be turned

off automatically if the temperature for the CPU is at or

below the specified value. Refer to Motherboard Layout on

Chapter 3 Block Diagram for CPU fan connectors.

Item

Selection

Manual

Mode

Manually set the fan speed

Smart Fan

Control:

It presets the target system temperature

(degree Celcius) at which the system fan will

start running if the fan is not yet turned on

with this mode. And the system fan can also

be turned off automatically if the tempera-

ture for the system is at or below the speci-

fied value.

Temp1/2/3/4: sets the temperature (in

0

C)

for the each of the following respective fan

speed (in duty cycle)

FanOut T1/T2/T3: sets the fan speed from

scale 1 to 255(full) in duty cycle

Note: The default value is the recommended

settings as it has been tested operational in our

lab.