beautypg.com

Appendix a, Using the ignition system manager (ism) – Lanner LVC-2000 User Manual

Page 24

background image

24

Using the Ignition System Manager (ISM)

Embedded and Industrial Computing

Appendix A

Appendix A:

Using the Ignition System

Manager (ISM)

The Ignition System Manager (ISM) is a software that

can monitor the system’s voltage level and configure the

features that the Power Ignition Module provides.
For sample ISM code, see ISM folder under LVC-2000 Utility

on the Driver and Manual CD.

Running the Program

Just double click the ISM.exe to launch the ISM.

The program can configure the following values:
Voltage: It shows the current power system.
Power Input System: Select either 12V or 24V for vehicular

power input.
Startup Voltage (V): If the DC-in voltage is not higher

than this value, the system will not be able to start up.
Shutdown Voltage (V): If the DC-in voltage is lower than

the shutdown voltage, the system will start shutdown

process automatically. (Refer to selector 2 of SW1 dip

switch on the mainboard.)
Power-on Delay (min/sec): Select power-on delay value

to indicate the time to delay powering on the system.

(Refer to the flow chart in Chapter 4)
Power-off Delay (hr/min/sec): Select power-off delay

value to indicate the time to delay powering off the system

(Refer to the flow chart in Chapter 4)
Serial Port: Select the serial communication port for the

ISM. Choose COM5.
D1/D2 Wakeup: Digital input triggering to enable

automatic wake-up function. Select this option and it will

start the system automatically once an input has been

triggered.
3G Wakeup: 3G SMS/Ring wake-up to enable automatic

wake-up function. Select this option and it will start the

system automatically through 3G Internet service.
DigitalOut: Check the box to turn on the output device

and check off the box to turn off the connected device.

After you have made changes, click Apply to apply the

changes to the Ignition controller or Cancel to cancel the

changes.

Click Cancel to exit the ISM program.

Note:

1.

You will have to enable (the default is enabled)

the selector 2 (Low Voltage Detection) of SW1 dip

switch on the mainboard to enable automatic

shutdown function. (Refer to Select MCU Detect

Function for power ignition behavior (SW1) in

Chapter 3 Board Layout.)

2.

DI1/DI2 Wakeup function is detected via pin 3

and 4 of MIO1 (Refer to MIO1 in Chapter 3 Board

Layout)

3.

Both DO1 and DO2 functions are connected

(controlled) via pin 15, 16, 19 and 20 of MIO1.

(Refer to MIO1 in Chapter 3 Board Layout)

4.

Refer to the flow charts in Chapter 4 for more

information.

.