4 technical data, Technical data, 4technical data – KACO Powador-gridsave User Manual
Page 11

Technical Data
Battery unit extension - Panasonic / Sanyo for Powador-gridsave
Page 11
4
Technical Data
Electrical data
Battery voltage [V]
48
Number of battery modules
1
2
3
4
5
Nominal capacity [kWh]
1.35
2.70
4.05
5.40
6.75
Max. charge or discharge output [kWh]
0.70
1.40
2.10
2.80
3.50
Cycles
4000 (at 90% discharge depth)
Service life
15 years
Table 3:
Electrical data
Mechanical data
Ambient temperature for operation [°C]
+5 to +40
Ambient temperature for storage [°C]
-20 … +20 (1 year) … +40 (3
months)
Humidity [%]
<95 (non-condensing)
Cooling
Forced cooling, temp. regulated
Temperature monitoring
Individual monitoring of
components with shutdown in the
event of excess temperature
Maximum installation elevation (m
above mean sea level]
2000
Protection class
IP20
Housing form
19" plug-in module, 2HU
H x W x D [mm] BMS
43x480x475
H x W x D [mm] battery/unit
79x480x400
Weight of BMS [kg]
2.5
Weight per battery/unit [kg]
19
Table 4:
Mechanical data