beautypg.com

3 protection concepts, 4 dimensions and weights, 5 inverter knockout dimensioning – KACO blueplanet 1502xi User Manual

Page 22: Hw d

background image

Page 24

blueplanet Operating and Installation Instructions 1502x - 2502x

Unit Description

4.3 Protection concepts

The following monitoring and protective functions are inte-
grated into blueplanet inverters:

– Overvoltage conductors/varistors to protect the power

semiconductors from high-energy transients on the grid
side.

– Temperature monitoring of the heat sink.

– EMC fi lters to protect the inverter from high-frequency

line interference.

– PV generator grounded varistors to protect the inverter

against bursts and surge pulses.

– Islanding detection according to IEEE 1547.

– Ground Fault Detector Interrupter (GFDI) according to

NEC 690.5.

4.4

Dimensions and weights

H

W

D

Figure 8: blueplanet dimensions refer to table

below for dimensions

Model

Height
(H)

Width
(W)

Depth
(D)

Weight

1502x

17

6/8

in

14 in

8

2/8

in

32 lbs

2502x

19

6/8

in

14 in

8

2/8

in

42 lbs

4.5 Inverter knockout

dimensioning

W

V

X

Y

Z

Y

Z

Figure 9: Inverter bottom knockout

dimensions

Model V W

X

Y

Z

1502x 6

in

9

2/8

in

4

2/8

in

3/4”

1/4”

2502x

6 in

9

2/8

in

4

2/8

in

3/4”

1/4”