KACO blueplanet 1502xi User Manual
Page 19
blueplanet Operating and Installation Instructions 1502x - 2502x
Page 21
Technical Data
Inverter – Electrical data
Model
1502x
2502x
Max. degree of effi ciency
95.9 % @ 240 V
AC
95.5 % @ 208 V
AC
96.0 % @ 240 V
AC
95.6 % @ 208 V
AC
CEC degree of effi ciency
95.5 % @ 240 V
AC
95.0 % @ 208 V
AC
95.5 % @ 240 V
AC
95 0 % @ 208 V
AC
Internal consumption
Night shutdown: 0.4 W @ 240 V
AC
/ 0.3 W @ 208 V
AC
Operation: < 5 W
Minimum grid-feed power
10 W
15 W
Maximum Output Fault Current
(AC) and Duration
30 A / 100 μs
50 A / 100 μs
Maximum Input Short Circuit
Current
21.45 A
21.45 A
Maximum Input Source Backfeed
Current to Input Source
0 A
Synchronization In-Rush Current
0 A
Voltage and Frequency Trip Time
< 160 ms
Voltage Trip Limit Accuracy
1.5 % of nominal value
Frequency Trip Limit Accuracy
± 0.06 Hz
Trip Time Accuracy
± 0.1 %
Circuit design
Galvanically isolating high frequency DC/DC converter with downstream self-commutated inverter
Clock frequency
17 kHz
Grid monitoring
complies with IEEE 1547
Table 6:
Inverter - Electrical Data