Technical Data

Inverter – Electrical data

Model

1502x

2502x

Max. degree of effi ciency

95.9 % @ 240 V

AC

95.5 % @ 208 V

AC

96.0 % @ 240 V

AC

95.6 % @ 208 V

AC

CEC degree of effi ciency

95.5 % @ 240 V

AC

95.0 % @ 208 V

AC

95.5 % @ 240 V

AC

95 0 % @ 208 V

AC

Internal consumption

Night shutdown: 0.4 W @ 240 V

AC

/ 0.3 W @ 208 V

AC

Operation: < 5 W

Minimum grid-feed power

10 W

15 W

Maximum Output Fault Current
(AC) and Duration

30 A / 100 μs

50 A / 100 μs

Maximum Input Short Circuit
Current

21.45 A

21.45 A

Maximum Input Source Backfeed
Current to Input Source

0 A

Synchronization In-Rush Current

0 A

Voltage and Frequency Trip Time

< 160 ms

Voltage Trip Limit Accuracy

1.5 % of nominal value

Frequency Trip Limit Accuracy

± 0.06 Hz

Trip Time Accuracy

± 0.1 %

Circuit design

Galvanically isolating high frequency DC/DC converter with downstream self-commutated inverter

Clock frequency

17 kHz

Grid monitoring

complies with IEEE 1547

Table 6:

Inverter - Electrical Data