6 technical data, Technical data, 6technical data – KACO Powador-piccoLOG User Manual
Page 19

Technical Data
Operating manual Powador-piccoLOG_EN
Page 19
6
Technical Data
General Information
Power supply
DC 24 V
Power consumption
1.7 W (typical)
Bus connection
integrated (cannot be switched off)
Network
Ethernet connection (10/100 Mbit)
Communication
1 x RS485/RS422
2 x RS232
2 x pulse input according to DIN 43864 (ISO)
4 x digital input for ripple control receiver
Frame size (W x H x D) in mm
152 x 107 x 37
Protection class
IP21
Weight
203 g
Ambient conditions
Operating temperature
0 to 55 °C
Storage temperature
-20 to 65 °C
Cables and wires
Cable types
Bus cable
RS485/422, twisted and shielded
Li2YCYv (TP) 2 x 2 x 0.5 mm2
1
)
Ethernet cable
Cat 5e / Cat 6 / Cat 7
RS232
J-Y(ST)Y 2 x 2 x 0.6 mm²
Power control
Cat 5e / Cat 6 / Cat 7
Maximum cable length permitted
Bus cable
1200 m
2)3)
Ethernet cable
100 m
3)
1)
We recommend the use of UNITRONIC® Li2YCYv (TP) cables, produced by
"Lapp Kabel" or equivalent. This cable is suitable for installation directly into
the earth.
2)
The use of repeaters is required for longer cables.
3)
Multiple cables of this length will require a hub.