beautypg.com

6 technical data, Technical data, 6technical data – KACO Powador-piccoLOG User Manual

Page 19

background image

Technical Data

Operating manual Powador-piccoLOG_EN

Page 19

6

Technical Data

General Information

Power supply

DC 24 V

Power consumption

1.7 W (typical)

Bus connection

integrated (cannot be switched off)

Network

Ethernet connection (10/100 Mbit)

Communication

1 x RS485/RS422
2 x RS232
2 x pulse input according to DIN 43864 (ISO)
4 x digital input for ripple control receiver

Frame size (W x H x D) in mm

152 x 107 x 37

Protection class

IP21

Weight

203 g

Ambient conditions

Operating temperature

0 to 55 °C

Storage temperature

-20 to 65 °C

Cables and wires

Cable types
Bus cable

RS485/422, twisted and shielded
Li2YCYv (TP) 2 x 2 x 0.5 mm2

1

)

Ethernet cable

Cat 5e / Cat 6 / Cat 7

RS232

J-Y(ST)Y 2 x 2 x 0.6 mm²

Power control

Cat 5e / Cat 6 / Cat 7

Maximum cable length permitted
Bus cable

1200 m

2)3)

Ethernet cable

100 m

3)

1)

We recommend the use of UNITRONIC® Li2YCYv (TP) cables, produced by

"Lapp Kabel" or equivalent. This cable is suitable for installation directly into

the earth.

2)

The use of repeaters is required for longer cables.

3)

Multiple cables of this length will require a hub.