5 connect ripple control receiver (optional), Connect ripple control receiver (optional) – KACO Powador-piccoLOG User Manual
Page 15

Installation and Start-up
Operating manual Powador-piccoLOG_EN
Page 15
5.5
Connect ripple control receiver (optional)
87654321
1 + 2
Reduction stage 0 ex works:
100 % power supply
3 + 4
Reduction stage 1 ex works:
60 % power supply
5 + 6
Reduction stage 2 ex works:
30 % power supply
7 + 8
Reduction stage 3 ex works:
0 % power supply
No signal
ex works: 70 % power supply
Invalid signal
ex works: 70 % power supply
Figure 5: Connect ripple control receiver
NOTE
To connect use a ready-made connection cable or a standard
Ethernet cable.
•
When using an Ethernet cable, cut off the connector at one
end and manufacture the cable according to the above pin
configuration.
Connect ripple control receiver
"
Connect ripple control receiver with digital port (see5.2 “Interface
overview").
"
Activate PowerControl by turning the PowerControl switch (see 4.2
“Device overview") to the "ON" position (see also 7.3 "PowerControl").
Limited configuration options: Inverter scan not possible!
"
Make adjustments using the software, if necessary.