3 Wiring and Connection

3.7.1 Connecting Regenerative Resistors

3-38

(3) SERVOPACKs: Model SGDV-550A, 260D

No built-in regenerative resistor is provided, so an external regenerative resistor unit is required. The regener-

ative resistor units are as follows:

Connect a regenerative resistor unit between the B1 and B2 terminals.

When using a regenerative resistor unit, use the factory setting for Pn600. If a non-Yaskawa regenerative resis-

tor is used, make the setting for Pn600.

Main Circuit

Power Supply

SERVOPACK Model

SGDV-

Applicable

Regenerative

Resistor Unit

Resistance

(

Ω)

Specifications

Three-phase
200 V

550A

JUSP-RA05-E

3.13

Eight 25

Ω (220 W) resistors are connected in

parallel.

Three-phase
400 V

260D

JUSP-RA18-E

18

Two series of two18

Ω (220 W) resistors each

are connected in parallel.

Regenerative Resistor Unit

JUSP-RA

-E

SERVOPACK