8 Troubleshooting
8.2.2 Troubleshooting of Warnings
8-28
A.95B
Command
Option Module
IF Command
Warning 2
The command option 
module sent a command 
that is not supported by 
the SERVOPACK.
–
Send a command that is supported by 
the SERVOPACK.
A.95D
Command
Option Module
IF Command
Warning 4
A latch command was
sent from the command 
option module during 
latch operation.
–
Review the input sequence for the 
latch command.
A.95E
Command
Option Module
IF Command
Warning 5
An unallowed com-
mand combination was 
output to the SERVO-
PACK from the com-
mand option module.
–
Send a command that can be com-
bined.
A.95F
Command
Option Module
IF Command
Warning 6
The command option 
module sent a command 
that is not supported by 
the SERVOPACK.
–
Send a command that is supported by 
the SERVOPACK.
A.960
Command
Option Module
IF
Communications
Warning
An error occurred in
communications 
between the SERVO-
PACK and command 
option module due to 
noise.
–
Take measures against noise.
The connection between 
the SERVOPACK and 
the command option 
module is faulty.
Check the connection between the 
SERVOPACK and the command 
option module.
Correctly connect the command 
option module.
A command option 
module fault occurred.
–
Replace the command option module.
A SERVOPACK fault 
occurred.
–
Replace the SERVOPACK.
Warning
Display
Warning Name
Situation at Warning
Occurrence
Cause
Corrective Actions