Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual
Page 272

8.1 Troubleshooting
8-21
8
T
roubleshooting
A.E61:
Command Option 
Module IF
Synchronization Error
3
The timing of synchronization 
between the SERVOPACK and 
command option module changed 
due to change in the communica-
tions cycle of the host controller 
connected to the command option 
module.
–
Turn the power supply OFF and 
then ON again. If the alarm occurs 
again, restart communications pro-
cessing from the host controller.
The connection between the 
SERVOPACK and the command 
option module is faulty.
Check the connection between the 
SERVOPACK and the command 
option module.
Correctly connect the command 
option module.
A command option module fault 
occurred.
–
Replace the command option mod-
ule.
A SERVOPACK fault occurred.
–
Replace the SERVOPACK.
A.E70:
Command Option 
Module Detection
Failure
The connection between the 
SERVOPACK and the command 
option module is faulty.
Check the connection between the 
SERVOPACK and the command 
option module.
Correctly connect the command 
option module.
The command option module is 
not connected.
–
Correctly connect the command 
option module.
A command option module fault 
occurred.
–
Replace the command option mod-
ule.
A SERVOPACK fault occurred.
–
Replace the SERVOPACK.
A.E71:
Safety Option Module 
Detection Failure
The connection between the
SERVOPACK and the safety 
option module is faulty.
Check the connection between the
SERVOPACK and the safety option 
module.
Correctly connect the safety option 
module.
The safety option module was 
disconnected. 
–
Execute Fn014 (Resetting configu-
ration error of option module) with 
using the digital operator or Sig-
maWin+ and turn the power supply 
OFF and then ON again.
A safety option module fault
occurred.
–
Replace the safety option module.
A SERVOPACK fault occurred.
–
Replace the SERVOPACK.
A.E72:
Feedback Option 
Module Detection
Failure
The connection between the 
SERVOPACK and the feedback 
option module is faulty.
Check the connection between the 
SERVOPACK and the feedback 
option module.
Correctly connect the feedback 
option module.
The feedback option module was 
disconnected. 
–
Execute Fn014 (Resetting configu-
ration error of option module) with 
the digital operator or SigmaWin+ 
and turn the power supply OFF and 
then ON again.
A feedback option module fault 
occurred.
–
Replace the feedback option mod-
ule.
A SERVOPACK fault occurred.
–
Replace the SERVOPACK.
A.E73:
Unsupported Option 
Module
A command option module fault 
occurred.
–
Replace the command option mod-
ule.
 A unsupported command option 
module was connected.
Refer to the catalog of the con-
nected command option module.
Connect a compatible command 
option module.
A.E74:
Unsupported Safety 
Option Module
A safety option module fault 
occurred.
–
Replace the safety option module.
 A unsupported safety option 
module was connected.
Refer to the catalog of the con-
nected safety option module.
Connect a compatible safety option 
module.
Alarm:
Alarm Name
Cause
Investigative Actions
Corrective Actions