4 Related Parameters and Functions
14
YASKAWA TM.A1000SW.117 Motion Control Custom Software Supplement
Table 8 Memobus Registers
U7-03
(0662h)
Distance To Go (Fine)
Dist To Go f
Distance from the destination. Displayed with fine
resolution (0.01 units).
N/A
0.01 Unit
U7-04
(0663h)
Commanded Destination
(Fine)
Commanded Dest f
Commanded destination. Displayed with fine
resolution (0.01 units).
N/A
0.01 Unit
U7-05
(0664h)
Distance From Home
(Coarse)
Dist From Home c
Distance from home (+ home offset) for absolute
applications, or distance from start of previous move
for relative applications. Displayed with coarse
resolution (1 unit).
N/A
1 Unit
U7-06
(0665h)
Distance To Go (Coarse)
Dist To Go c
Distance from the destination. Displayed with coarse
resolution (1 unit).
N/A
1 Unit
U7-07
(0666h)
Commanded Destination
(Coarse)
Commanded Dest c
Commanded destination. Displayed with coarse
resolution (1 unit).
N/A
1 Unit
U7-08
(0667h)
Commanded Speed
Reference
Cmd Speed Ref
Commanded speed for the selected destination.
N/A
0.01 Hz
U7-09
(0668h)
Gray Code Encoder Position
Gray Code Pos
Position of the gray code absolute encoder counts in
multiples of tens.
N/A
1 dct
(deka-count)
<1> The actual units text displayed in the digital operator is determined by parameter P1-10. Actual distance in encoder counts is calculated by
multiplying the monitor output by P1-09. If the monitor is in excess of 327.67 units, the display will be clamped at 327.67 units. If the monitor
is less than -99.99 units, the display will be clamped at –99.99 units .
<2> The actual units text displayed in the digital operator is determined by parameter P1-10. Actual distance in encoder counts is calculated by
multiplying the monitor output by P1-09. If the monitor is in excess of 32767 units, the display will be clamped at 32767 units. If the monitor is
less than -9999 units, the display will be clamped at –9999 units.
Memobus Address
Description
6D0h
Memobus Communication Speed Reference during a Move
Effective only when P1-02 = 1.
6D1h
Memobus Communication Position Reference (Engineering Units)
Actual position reference in encoder counts = 6D1h × P1-09.
Range is: 0.00 to 655.35 units. Effective only when P1-02 = 1.
6D0h
Memobus 32-bit Communication Position Reference (low word)
In quadrature encoder counts. Effective only when P1-02 = 3.
6D1h
Memobus 32-bit Communication Position Reference (high word)
In quadrature encoder counts. Effective only when P1-02 = 3.
6E0h
32 Bit Distance From Home (low word) - Read Only
Distance from home (+ home offset) for absolute applications, or distance from start of previous move for
relative applications. In quadrature encoder counts.
6E1h
32 Bit Distance From Home (high word) - Read Only
Distance from home (+ home offset) for absolute applications, or distance from start of previous move for
relative applications. In quadrature encoder counts.
No.
(Addr.
Hex)
Parameter Name
Digital Operator Display
Description
Analog Output
Scaling
Unit
Control Mode
Access Level
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes