VCD 723-A003

3

03

03

9.6

1.00

VCD 723-A005

5

04

04

16

2.00

VCD 723-A7P5

7.5

05

05

24

2.00

230

VCD 723-A010

10

06

06

32

2.00

VCD 723-A015

15

07

07

48

2.00

VCD 723-A020

20

08

08

64

2.00

VCD 723-A030

30

0A

10

96

2.00

VCD 723-A050

50

0C

12

160

2.00

VCD 723-B003

3

23

35

4.8

1.00

VCD 723-B005

5

24

36

8

2.00

VCD 723-B010

10

26

38

16

2.00

VCD 723-B015

15

27

39

24

2.00

VCD 723-B020

20

28

40

32

2.00

VCD 723-B030

30

2A

42

48

2.00

460

VCD 723-B040

40

2B

43

64

2.00

VCD 723-B060

60

2D

45

76.8

2.00

VCD 723-B075

75

2E

46

128

2.00

VCD 723-B100

100

2F

47

165

2.00

VCD 723-B150

150

31

49

224

2.00

VCD 723-B200

200

33

51

300

2.00

VCD 723-B300

300

35

53

450

2.00

VCD 723-B400

400

36

54

600

2.00

RATED

VCD MODEL

HP

Sn-01 Sn-01

CONTINUOUS

POWER

INPUT

NO.

HEX

DEC

RATED

LOSS RIDE

VAC

CURRENT

THRU

TIME (CN-19)

Appendices

86

Node, Channel and Subchannel Assignments

9/15/93

ON-01 Setting
ON-01 is factory set for 0000 and should not be changed. This enables the
inverter fault circuit which detects tach connection.

ON-02 Setting
ON-02 is factory set for 0010. This determines whether the inverter utilizes the
motor thermistor or not:

0000 = Control with thermistor
0010 = Control without thermistor

SN-01 Settings
SN-01 sets the capacity of the VCD 723 per the following table. SN-01 can be
set either by using a numo block to write the decimal value to [260-101-0] or by
using the geth block to write the hex value to [723-101-~]. If SN-09 is set for
low noise operation, the values shown for continuous current must be reduced
by 20%. SN-01automatically determines the setting of CN-19.