Yaskawa VCD 723 User Manual
Page 92

VCD 723-A003
3
03
03
9.6
1.00
VCD 723-A005
5
04
04
16
2.00
VCD 723-A7P5
7.5
05
05
24
2.00
230
VCD 723-A010
10
06
06
32
2.00
VCD 723-A015
15
07
07
48
2.00
VCD 723-A020
20
08
08
64
2.00
VCD 723-A030
30
0A
10
96
2.00
VCD 723-A050
50
0C
12
160
2.00
VCD 723-B003
3
23
35
4.8
1.00
VCD 723-B005
5
24
36
8
2.00
VCD 723-B010
10
26
38
16
2.00
VCD 723-B015
15
27
39
24
2.00
VCD 723-B020
20
28
40
32
2.00
VCD 723-B030
30
2A
42
48
2.00
460
VCD 723-B040
40
2B
43
64
2.00
VCD 723-B060
60
2D
45
76.8
2.00
VCD 723-B075
75
2E
46
128
2.00
VCD 723-B100
100
2F
47
165
2.00
VCD 723-B150
150
31
49
224
2.00
VCD 723-B200
200
33
51
300
2.00
VCD 723-B300
300
35
53
450
2.00
VCD 723-B400
400
36
54
600
2.00
RATED
VCD MODEL
HP
Sn-01 Sn-01
CONTINUOUS
POWER
INPUT
NO.
HEX
DEC
RATED
LOSS RIDE
VAC
CURRENT
THRU
TIME (CN-19)
Appendices
86
Node, Channel and Subchannel Assignments
9/15/93
ON-01 Setting
ON-01 is factory set for 0000 and should not be changed. This enables the
inverter fault circuit which detects tach connection.
ON-02 Setting
ON-02 is factory set for 0010. This determines whether the inverter utilizes the
motor thermistor or not:
0000 = Control with thermistor
0010 = Control without thermistor
SN-01 Settings
SN-01 sets the capacity of the VCD 723 per the following table. SN-01 can be
set either by using a numo block to write the decimal value to [260-101-0] or by
using the geth block to write the hex value to [723-101-~]. If SN-09 is set for
low noise operation, the values shown for continuous current must be reduced
by 20%. SN-01automatically determines the setting of CN-19.