Node, channel and subchannel assignments, Vcd 723 constants – Yaskawa VCD 723 User Manual
Page 90

Appendices
84
Node, Channel and Subchannel Assignments
9/15/93
Every device in a MicroTrac system is identified with a Node number, a Channel
number, and a Subchannel number, regardless of whether the device uses the
Local Area Network or not. These identifiers have different significance for each
device and some devices may not need all three fields to provide a unique
identification. This appendix lists each device type relating to the VCD 723, and
describes the significance of each field for that device.
Node, Channel
and Subchannel
Assignments
VCD 723
Constants
CN-09 Settings
CN-09 sets the digital tach pulses per revolution. This is normally set for either
1024 or 2500 PPR depending upon the type of tach used on the motor.
DN-01 thru DN-18 Settings
DN-01 thru DN-18 set the motor constants per the following tables:
Dn-01
MOTOR BASE SPEED
1750
RPM
Dn-02
MOTOR MAXIMUM SPEED
1750
RPM
Dn-03
NUMBER OF MOTOR POLES
4
~
Dn-04
MOTOR NO LOAD VOLTAGE
PER TABLE
VAC
Dn-05
MOTOR RATED PRIMARY CURRENT
PER TABLE
AAC
Dn-06
RATED SLIP FREQUENCY
PER TABLE
HZ
Dn-07
EXCITATION CURRENT REFERENCE
PER TABLE
%
Dn-08
PRIMARY RESISTANCE, USED WITH OPT TRQ BOARD
PER TABLE
%
Dn-09
LEAKAGE COEFFICIENT, USED WITH OPT TRQ BOARD
PER TABLE
%
Dn-10
MOTOR IRON LOSS
PER TABLE
%
Dn-11
MOTOR MACHINERY LOSS
PER TABLE
%
Dn-12
SECONDARY CIRCUIT TIME CONSTANT
PER TABLE
MSEC
Dn-13
LEAKAGE SAT COEF, USED WITH OPT TRQ BOARD
1.20
~
Dn-14
ROTOR HEAT GAIN
0.00
~
Dn-15
ROTOR HEAT TIME CONSTANT
30
MIN
Dn-16
IRON CORE SATURATION COMP COEFFICIENT 1
0.5
~
Dn-17
IRON CORE SATURATION COMP COEFFICIENT 2
0.75
~
Dn-18
MOTOR OVERHEAT TEMPERATURE
155
°C
CONSTANT
DESCRIPTION
INITIAL VALUE
UNITS