beautypg.com

Introduction, Ratings and specifications, Table 1. motor control specifications - continued – Yaskawa VCD 723 User Manual

Page 14

background image

1

Introduction

8

Ratings and Specifications

9/15/93

SECTION C. ALL GPD 503 s (CONTINUED)

Control Method

Digital flux vector, Sine-coded PWM

Speed Control

Range

1:1000 operation possible even at stall

Precision

Digital ref.: ± 0.01% (–10 to +40°C, +14 to +140°F)
Analog ref.: ± 0.1% (25 ± 10°C, 77 ± 50°F)

Control

Speed Reference

Digital Operator reference: 0.01 Hz (12 bits)

Characteristics

Setting Resolution

Analog reference: 0.06 Hz/60Hz (10 bits)

Auto Speed Reference Signal

0 to +10 VDC (20k

), or 4 to 20 mA (250

)

Accel / Decel Time

0 to 3000 sec (resolution: 0.1 sec.)
(Accel / Decel times set independently)

Torque Limit

Setting range: 0 to 300%. Forward/Reverse set independently

Selectable Functions

Multi-step speed operation (9 steps max.), S-curve accel/decel,
zero speed control, servo lock, arbitrary torque detection, etc.

Inverter

Overcurrent, overvoltage, cooling fin overheat, undervoltage,
cooling fan failure, grounding, etc.

Protective

Motor

Overload, overheat, overspeed

Functions

System

Excessive speed deviation, open-phase detection, continuous
operation during momentary power loss (immediate stop at end
of programmed ride-thru time, 2 sec. max.)

(See Note 3)

Environmental

Ambient Temperature

–10 to +45°C (+14 to +113°F)

Conditions

Storage Temperature

(See Note 4)

–20 to +60°C (–4 to +140°F)

Humidity

90% RH (no condensation)

Vibration

1 G at less than 20 Hz, up to 0.2 G at 20 to 50 Hz.

SECTION D

Rated speed

1750 rpm (4 poles)

Pulse Generator

1024 ppr (standard) Higher rates are available.

Thermistor

Standard

Load Connection

Direct coupling or belt drive

Insulation Type

Class F

Ambient Temperature

–20 to +40°C (–4 to +104°F)

Location

Indoor

NOTES:

(1)

Low noise operation can be selected by setting of Sn-09 : 0XXX = General Use (low carrier frequency – 2.08 kHz);
1XXX = Low Noise Operation (high carrier frequency - 12.5 kHz). Rated current is 80% of General Use rated current.

(2)

100% reference current is Continuous Rated Current for Low Noise Operation or General Use.

(3)

For a drive rated 230V 5HP or less, or 460V 3HP or less, standard max. ride-thru time is 1 sec (1000 msec). The
max. ride-thru time can be extended to 2 sec (2000 msec) by adding an optional external mounting capacitor unit.

(4)

Temperature during shipping. Storing in this temperature for a long period may deteriorate main circuit capacitor.

SECTION D. All VCM’s

SECTION C. All VCD 723’s

Table 1. Motor Control Specifications - Continued