Troubleshooting/Maintenance

72

Troubleshooting Flowcharts

9/15/93

Chart 13. Power Supply Verification

ARE SUPPLIES ON

TEST POINTS PER

TABLE 9?

YES

REPLACE MICROTRAC
CIRCUIT CARD.

NO

REPLACE DRIVE
POWER SUPPLY.

CHECK VOLTAGE BETWEEN

TERMINAL 15 (+15V) AND

17 (COMMON) ON

DRIVE FOR +15 VDC.

YES

REPLACE CABLE
BETWEEN MICROTRAC
CIRCUIT CARD AND
DRIVE.

NO

TP1 - TP13

For use by MagneTek Engineering

TP14

Analog Input 0 (+/-10 VDC)

TP15

Analog Input 1 (+/-10 VDC)

TP16

Analog Output 0 (+/-10 VDC)

TP17

Analog Output 1 (+/-10 VDC)

TP18

+10VREF

TP19

-10VREF

TP20

-15 VDC Supply

TP21

+5 VDC Supply

TP22

+15 VDC Supply

TP23

+24 VDC Supply

TP24

Power Supply Common

TP25

Power Supply Common

Table 9. AC MicroTrac Circuit Card Test Points