Yaskawa MP2000iec User Manual
Page 39

11 MECHATROLINK-II
YASKAWA America, Inc. MP2300iec Hardware Manual YAI-SIA-IEC-2R
39
Hardware Specifications
The table below shows the hardware specifications of REP2000.
s
n
o
i
t
a
c
i
f
i
c
e
p
S
m
e
t
I
Name
REP2000 Repeater
Model Number
JEPMC-REP2000
Communication
board
Applicable Communication
Protocol
MECHATROLINK-II (10 Mbps)
Number of
MECHATROLINK Ports
2 (CN1 and CN2)
Connect either CN1 or CN2 to the Master-side network,
and the other to the extended network.
Master-side Port
Connect to the Master-side network
No. of connectable slave stations for Master-side network:
15 stations for the network distance of 30m max.
14 stations for the network distance of 50m max.
Refer to
Maximum Number of Slave Stations of 11.2.5
Restrictions for details
Extended-network-side Port
Connect to the extended network
No. of connectable slave stations for extended network:
16 stations for the network distance of 30m max.
15 stations for the network distance of 50m max.
Refer to
Maximum Number of Slave Stations of 11.2.5
Restrictions for details
Arbiter
First request for higher priority. CN1 has a priority at
simultaneous requests
Terminator
One (130
Ω) for each port
Indicator Lamps
(LED)
Status Indication
3 LED indicator lamps
POWER (green): Power ON
TX1 (green): CN1 busy (in transmitting data)
TX2 (green): CN2 busy (in transmitting data)
Others
Mounting Orientation
Vertical or horizontal (The nameplate upward)
Required External Power
Supply
+24 VDC (+19.2 to +28.8V), 100 mA
Dimensions in mm
30
× 160 × 77 (W× H × D)
Mass
0.4 kg