GPD515/G5 to F7

__________________________

PL.F7.02.TransitionGuide 6/5/06
Page 6 of 40
Yaskawa Electric America, Inc

GPD515/G5 to F7 Feature Differences

Feature

Item

Yaskawa GPD515/G5

Yaskawa F7

200V

230V 0.5 to 150HP

1

240V 0.5 to 150HP (ND)

2

400V

460V 0.5 to 400HP

1

480V 0.5 to 500HP (ND)

600V

2 to 200HP

N/A

HP Range

Input Voltage

Rated Voltage

3-phase, 200-230Vac
3-phase, 380-460Vac

3-phase, 200-240Vac
3-phase, 380-480Vac

PWM Carrier Frequency

Range

See Appendix 1

See Appendix 1

Max. Output Frequency

Hz 400Hz

(800Hz

optional)

300Hz (HD) 400Hz (ND)

1000 Hz optional

Display

2 Line x 16 Character LCD

5 Line x 16 Character LCD

Keypad Design

Copy Function

No

Yes

Digital Input Terminal

NPN/PNP NPN

Switchable

NPN/PNP

Open Collector

2

0

Digital Output Terminal

Relay Output

1 x Form A, 1 x Form C

3 x Form A, 1 x Form C

Analog Output

Output Level

2 channels

0-10V or –10V to +10V

(9 bit plus sign)

2 channels

with independent level selections

0-10V (10 bit plus sign) or

–10-+10V or (10 bit plus sign) or

4-20ma (10 bit plus sign)

Qty. 0

1

Pulse Input

Input Freq.

Not Available

1-32kHz

Qty. 0

1

Pulse Output

Output Freq.

Not Available

0-32kHz

Quick Disconnect
Terminals

Type No

Yes

(Phoenix)

Auto Tuning

Rotating/Stationary Rotating

Rotating/Stationary/

Primary Resistance

Preset Speeds

Qty.

8

17

Bi/Uni-Directional Uni-Directional

Bi-Directional

Speed Search

Method Current

Current/

Speed

Auto Restart

Time Between

Attempts

180.0 sec continuous

(not selectable)

0.0 – 5.0 sec

(selectable)

Energy Savings Mode

Man/Auto

Manual

Man/Auto

DC Injection Function

At Start/At Stop

At Start/At Stop

At Start/At Stop +HSB during stop

DB Transistor

Built-in to 10HP (230V)
Built-in to 25HP (460V)

Built-in to 25HP

Braking Function

Special

No

High Slip Braking

Cooling Fan On/Off
Control

Power/Run No

Run

Based

Timer Function

On/Off Delay

On/Off Delay (0-25.5 sec)

On/Off Delay (0-3000 sec)

Fault Code Additions

-

n/a

10 additional

Torque Limit / Current
Limit /
Stall Prevention

-

Stall Prevention

During Accel/Run/Decel (V/F)

Torque Limit in 4 Quadrants

(Vector)

Stall Prevention

During Accel/Run/Decel (V/F)

Torque Limit in 4 Quadrants (Vector)

Software current limit

(HD=150%/ND=120%)

1

Larger G5 models available by HHP modular design.

2

HD=Heavy Duty, ND=Normal Duty