7 Related Parameters

52

YASKAWA ELECTRIC TOBP C730600 29G 1000-Series Option JVOP-180 Installation Manual

b1-01

Frequency
Reference
Selection 1

YES

N/A

N/A

Selects the source of the frequency reference.
0: Operator -Digital preset speed d1-01 to d1-
17
1: Terminals - Analog input terminal A1 or A2
2: MEMOBUS/Modbus serial
communications
3: Option PCB
4: Pulse Input (Terminal RP)

Default: 1
Range: 0 to 4

b1-02

Run
Command
Selection 1

YES

YES

YES

Selects the Run command input source.
0: Operator -RUN and STOP keys on the LCD
Operator Option
1: Digital input terminals S1 to S7
2: MEMOBUS/Modbus serial
communications
3: Option PCB

Default: 1
Range: 0 to 3

b1-15

Frequency
Reference 2

YES

N/A

N/A

Selects the frequency reference input source.
0: Operator - Digital preset speed d1-01 to d1-
17
1: Terminals - Analog input terminal A1 or A2
2: MEMOBUS/Modbus serial
communications
3: Option PCB
4: Pulse Input (Terminal RP)

Default: 0
Range: 0 to 4

b1-16

Run
Command
Source 2

YES

N/A

N/A

Selects the Run command input source.
0: Operator - RUN and STOP keys on the LCD
Operator Option
1: Digital input terminals S1 to S7
2: MEMOBUS/Modbus serial
communications
3: Option PCB

Default: 0
Range: 0 to 3

b1-18

Voltage
Reference
Source

N/A

YES

N/A

Sets the input source for the DC bus voltage
reference.
0: LED operator or LCD operator
1: Control circuit terminal (analog input)
2: MEMOBUS/Modbus communications
3: Option card
7: Input voltage based control 1
8: Input voltage based control 2

Default: 0
Range: 0 to 3,
7, 8

o2-01

LOCAL/
REMOTE
Key
Function
Selection

YES

YES

N/A

Enables/Disables the option LOCAL/
REMOTE key.
0: Disabled
1: Enabled

Default: 1
Range: 0, 1

No.

Name

Unit

Description

Values

A1000/

V1000 D1000 R1000