5 Installation Procedure
YASKAWA ELECTRIC TOBP C730600 29G 1000-Series Option JVOP-180 Installation Manual
25
■
Internal/Flush-mount Installation
The internal flush-mount installation method requires an installation support that is
purchased separately.
Refer to Item Names and Part Numbers (Sold Separately) on
for information regarding the installation support and mounting hardware.
illustrates how to install Installation Support Kit A.
1.
Cut an opening in the enclosure panel for the option according to
2.
Mount the option to the installation support (sold separately).
3.
Mount the installation support and option to the enclosure panel.
Figure 13
Figure 13 Internal/Flush Mount Installation
Note: For environments with a significant amount of dust or other airborne debris, use a gasket
between the enclosure panel and the option.
Figure 14
Figure 14 Panel Cut-out Dimensions (Internal/Flush-mount Installation)
Enclosure panel
Option
Installation Support Kit A
M4 × 10 (0.39)
Phillips truss head screw × 4
(for panel widths between 1 (0.04)
and 1.6 (0.06))
M3 × 6 (0.24)
Phillips recessed pan head
machine screw × 2
Unit: mm (in.)
120 (4.72)
Unit: mm (in.)
45 (1.77)
89
+0.5 0
35
)
(
+0.02 0
59
+0.5
0
2.32 )
(
+0.02
0