beautypg.com

Option dimensions, Installing the option, 5 installation procedure – Yaskawa JVOP-180 LCD User Manual

Page 23

background image

5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 29G 1000-Series Option JVOP-180 Installation Manual

23

Option Dimensions

Figure 10

Figure 10 Dimensions

<1> Use only Yaskawa cables or cables recommended by Yaskawa. Refer to

Item

Names and Part Numbers (Sold Separately) on page 11

.

Installing the Option

The option mounts to an enclosure two different ways:

External/face-mount installs the operator outside the enclosure panel.

Internal/flush-mount installs the operator inside the enclosure panel.

Table 12 Option Installation Methods

Installation Method

Description

Notes

External/Face-mount

Simplified installation with the option is mounted on the
outside of the panel with two screws.

Internal/Flush-mount

Encloses the option in the panel. The front of the option is
flush with the outside of the panel.

Requires purchase of
separate items.

Refer to Item

Names and Part Numbers
(Sold Separately) on
page 11

.

<1>

90 (3.54)

78 (3.07)

60 (2.36)

7.9

(0.31)

minimum 50 (1.97)

Unit : mm (in.)

12.2

(0.48)

1.6 (0.06)

Installation holes

(2-M3 screws, depth 5 (0.2))

44 (1.73)

15

(0.59)

S / N : J007XE273710001

This manual is related to the following products: