beautypg.com

SMA SB 4200TL Multi-String User Manual

Page 27

background image

SMA

Technologie AG

Device Description

Operating Instructions

SB4200-12:FE4804

Page 27

Messages of the Sunny Display During Operation

The Sunny Display presents all relevant operating data one screen after the other.
The images on the side indicate the messages. Each message is displayed for 5 se-
conds. After all messages have been displayed the display starts from the beginning
again.

First the „E-Today“ (total energy produced on this
day) is displayed together with the current operating
status.

The message is followed by the current power and
the current grid voltage.

The incoming voltage for the two input strings is listed
separately,

as well as the incoming DC power:

Finally the accumulated yield of the device since in-
stallation is displayed together with the total opera-
ting hours:

Energy produced today

and current operating status

E-today 3.86kWh
Mode MPP

Current AC Power

and AC voltage

Pac 903W
Uac 230V

Current DC voltages of the

separate strings

UPVA UPVB
600V 575V

Different currents from the 2 strings

PA/W PB/W
1325 1275

Total energy yield and

total operating hours

E-Total 724.4kWh
h-Total 512h