SMA SB 4200TL Multi-String User Manual
Page 27
SMA
Technologie AG
Device Description
Operating Instructions
SB4200-12:FE4804
Page 27
Messages of the Sunny Display During Operation
The Sunny Display presents all relevant operating data one screen after the other.
The images on the side indicate the messages. Each message is displayed for 5 se-
conds. After all messages have been displayed the display starts from the beginning
again.
First the „E-Today“ (total energy produced on this
day) is displayed together with the current operating
status.
The message is followed by the current power and
the current grid voltage.
The incoming voltage for the two input strings is listed
separately,
as well as the incoming DC power:
Finally the accumulated yield of the device since in-
stallation is displayed together with the total opera-
ting hours:
Energy produced today
and current operating status
E-today 3.86kWh
Mode MPP
Current AC Power
and AC voltage
Pac 903W
Uac 230V
Current DC voltages of the
separate strings
UPVA UPVB
600V 575V
Different currents from the 2 strings
PA/W PB/W
1325 1275
Total energy yield and
total operating hours
E-Total 724.4kWh
h-Total 512h