beautypg.com

SMA SB 4200TL Multi-String User Manual

Page 23

background image

SMA

Technologie AG

Device Description

Operating Instructions

SB4200-12:FE4804

Page 23

Device Failure

When the failure occurs, the yellow LED is on for five seconds and then starts the blin-
king code by staying off for three seconds and then blinking five times in short inter-
vals. The code is sent three times.

If the failure persists, the signal starts from the beginning.

The Sunny Boy is in a state it cannot leave for normal operation. Presumably there is
an internal failure in the device.

A qualified electrician has to examine the device.

5 s

3 s

1 s

1 s

1 s 1 s

LED on

LED off

Yellow LED is blinking 5
times in short intervals.

The signal is repeated 3 times and
then start from the beginning.