Assembly

Installation Guide

RS485-QM-IA-eng-IUS111610

21

3. Shorten the cable sheath by

1

2

in. (15 mm) (B). Leave the cable shield on the cable.

4. Shorten the cable shield by

1

2

in. (15 mm) (B) and fold it back.

5. Cut off unused insulated conductors at the cable sheath to prevent a short-circuit. 3 conductors

are required. 2 conductors must be twisted.

6. Strip the conductors to a length of

1

4

in. (6 mm) (C).

7. Cover the shield with the delivered conductive

adhesive foil.

☑ The cable is prepared.

5.4 Installing the Cable Pipe and Introducing the Cable into the

Inverter

1. Push out the filler-plugs of an unused cable opening from the inside of the SMA DC-Disconnect

enclosure.

2. Install the cable pipe on the free opening of the SMA DC-Disconnect. Use matching nuts on the

inside to screw the cable pipes to the the SMA DC-Disconnect.

3. If you want to install a fault sensor on the multi-function relay: Install the distribution box on the

cable pipe. The distribution box lets you lead the power supply of the multi-function relay and
the RS485 data cable to the DC-Disconnect.

4. Connect the cable pipe for the RS485 data cable and the cable pipe for the power supply of

the multi-function relay to the distribution box.

NOTICE

Damage to the SMA DC-Disconnect through enlargement of the cable pipe openings.

• Do not enlarge openings for the cable pipes. The openings are intended for the

installation of cable pipes with a size of up to

3

4

in. (19 mm).