2 sunny data via rs232, 3 sunny data via rs485, Sunny data via rs232 – SMA SB 3300TL User Manual

Page 34: Sunny data via rs485

background image

Plant Monitoring

SMA

Technologie AG

Page 30

SB3300TL-11:FE1905

Operating Instructions

6.1.2 Sunny Data via RS232

Communication via cable
(one single Sunny Boy or Sunny Mini Central)
Requirements: The Sunny Boy or Sunny Mini Central has to be equipped with the
RS232 Piggy-Back. The PC is connected directly to the COM1 or COM2 port of the
PC. The installation of the RS232 cable is described in the Installation Guide of the
Sunny Boy 3300TL.

6.1.3 Sunny Data via RS485

Communication via cable
(with up to 50 Sunny Boys or Sunny Mini Centrals)
Requirements: All Sunny Boys and Sunny Mini Centrals have to be equipped with an
RS485 Piggy-Back. The PC is connected to the COM1 or COM2 power via an
RS485/RS232 interface converter. The installation of the RS485 cable is described
in the Installation Guide of the Sunny Boy 3300TL.