3.3.4 Description of Operating States

Stand-by at Night

The Sunny Boy 3300TL is in so-called
stand-by operation. This state is
reached if the input power at the in-
verter is too low for feeding opera-
tion (all string voltages are below
125 V) and not sufficient for normal
operation.

Initialization

The on-board computer of the Sunny
Boy 3300TL is in the initialization
phase. The DC input voltage at the
Sunny Boy is above approx. 125 V.
Power is already supplied to the inter-
nal board, but is not yet sufficient for
grid feeding. Data transmission is not
possible yet.

Feeding Operation

The Sunny Boy 3300TL has success-
fully completed the self-test of the
measurement electronics and the
MSD and starts feeding to the grid.

MPP operation (default):

The Sunny Boy 3300TL automatically
determines the MPP voltage of the
PV-generator.

All LEDs are off

All LEDs are on or
blinking

Green LED is on