Messages of the Sunny Display during Operation
The Sunny Display presents all relevant operating data on one screen after the other.
The four images below indicate the messages. Each message is displayed for 5 sec-
onds. After all messages have been displayed the display restarts from the begin-
ning.
First the total energy produced this day („E-Today“)
is displayed together with the current operating sta-
tus.
Then the current power and the current grid voltage
are displayed.
Next, the input (DC) power and the DC voltage are
displayed.
Finally, the accumulated yield of the device since in-
stallation together with the total operating hours are
displayed:
Message of the Sunny Display in case of a Failure
In case of a failure the Sunny Display switches to „Failure“ and the background illu-
mination is activated.
The bottom line indicates the type of failure for 5 sec-
onds.
Failures resulting from a specific value that e.g. ex-
ceeds a limiting are specified with the value that
caused the failure as well as the current value.
The normal operating data is displayed after 5 sec-
onds.
The display restarts from the beginning in case the failure is still present. For detailed
information concerning the failure messages see chapter 7.4 "Measurement Chan-
nels and Messages" (page 39).
Energy produced today
and current operating status
E-today 3.86kWh
Mode MPP
Current AC Power
and AC voltage
Pac 903W
Uac 230V
Current DC power and
DC voltage
PPV 1325W
UPV 600V
Total energy yield and
total operating hours
E-Total 724.4kWh
h-Total 512h
Indication of a failure
and failure type
Error
Uac-Bfr
Display of the value that caused the
failure and the current value
at: 261V
present: 245V