SB2800i-11:SE0504

The impedance at the AC connection point of the Sunny Boy
3000 must be below 2 Ohm in order to ensure a reliable function
of the anti-islanding unit. You should furthermore have a suitable
cable cross-section in order to keep the losses below 1 % at
nominal power. The according losses with respect to cable length
and cross-section are illustrated below:

Fig. 4.1:

Losses in AC cable

The Sunny Boy 2800i is designed for 230 V grids. The voltage
should be within 198 V and 260 V and the frequency should be
within 49.8 Hz and 50.2 Hz.

Table 4.2: Limits for AC output of the Sunny Boy 2800i

Limits for AC Output

Voltage range

198 V ... 260 V

Frequency range

49.8 Hz ... 50.2 Hz

Voltage range
(without ENS)

180 V ... 260 V

Frequency range
(without ENS)

45.5 Hz ... 54.5 Hz

Limits for AC output

198 V ... 260 V