3. To read off the firmware version of the integrated communication interface (e.g. SMA
Speedwire/Webconnect data module), select the parameter group Type label > Type label
. Here, the firmware version of the communication interface is displayed in the field Software
package.
4. To read off the firmware version of the inverter, select the parameter group Device
components > Type label > Central assembly. Here, the firmware version is displayed in
the field Software version.
10.4 IP Addresses of the Devices
10.4.1 Reading Off the IP Address of the Cluster Controller
You have two options for reading off the IP address of the Cluster Controller:
• Reading off the IP address from the display
• Reading off the IP address from the user interface
Reading off the IP address from the display
• On the Cluster Controller, select the display view External communication and read off the
IP address.
Reading off the IP address from the user interface
1. Select the Cluster Controller in the system tree and select the menu Settings in the device
menu.
2. Select the parameter group External communication and read off the IP address:
• If the Cluster Controller automatically receives its IP address via DHCP, read off the IP
address in the group DHCP.
• If the Cluster Controller has received a static IP address, read off the IP address in the
group Ethernet.
10.4.2 Reading Off the IP Address of the Inverter
You have two options for reading off the IP address of the inverter:
• Reading off the IP address from the inverter display
• Reading off the IP address from the user interface of the Cluster Controller
Reading off the IP address from the inverter display
• Tap twice on the enclosure lid.
☑ The display alternates automatically between the firmware version, the serial number of
the inverter, the NetID, IP address, subnet mask, the configured country data set, and the
display language.
Reading off the IP address from the user interface of the Cluster Controller
1. In the system tree, select the desired inverter and select the menu Instantaneous values in
the device menu.
2. Select the parameter group System communication > Speedwire and read off the IP
address.
10 System Management and Replacing Components
SMA Solar Technology AG / SMA America, LLC
User Manual
ClusterController-BA-en-14