beautypg.com

3 preparing bluetooth communication, 4 commissioning the sma flexible storage system, 3 preparing bl – SMA SI 3.0-11 Quick Reference Guide V.4.0 User Manual

Page 27

background image

SMA Solar Technology AG

7  Commissioning

Installation Manual - Quick Reference Guide

FSS-IS-en-40

27

Procedure:

1. Switch to expert mode on the Sunny Remote Control (see Sunny Island inverter operating manual).
2. Set the parameter 232.07 GdFrqMax to 50.2 Hz.
3. Set the parameter 232.15 GdFrqMaxDel to 0.05 Hz.
4. Set the parameter 232.08 GdVldTm to 30 s.
5. If your grid operator specifies a maximum grid feed-in per line conductor, set the parameter

210.03 InvChrgCurMax to the value specified by the grid operator.

7.3 Preparing BLUETOOTH Communication

To enable communication between SMA BLUETOOTH devices in the SMA Flexible Storage System, all devices must be

set to the same NetID (identification number for SMA Bluetooth network). The NetID is used to distinguish between

systems with SMA BLUETOOTH operating in close proximity to one another.

Procedure:

1. For PV inverters with integrated BLUETOOTH interface that communicate via Speedwire, set NetID 0 (see PV inverter

installation manual). This deactivates communication via BLUETOOTH.

2. Determine the NetID of the BLUETOOTH system:

• Install Sunny Explorer on a computer. Either run the installation file on the CD provided or download free of

charge at www.SMA-Solar.com.

• Determine a free NetID for the BLUETOOTH system using Sunny Explorer (see Sunny Explorer user manual).
• Quit Sunny Explorer. This will ensure that the BLUETOOTH network is set up via the Sunny Home Manager.

3. Set the determined NetID on the Sunny Home Manager and on all

devices with active BLUETOOTH interface (see documentation of

the BLUETOOTH devices). Note that the NetID must not be set to 1

if the Sunny Home Manager is intended to communicate with more

than one BLUETOOTH node.

7.4 Commissioning the SMA Flexible Storage System

Required data for registration in Sunny Portal:

Device/customer data Required data and explanation
Sunny Home Manager

• Serial number (PIC) and registration ID (RID)

Register the new system in Sunny Portal using the PIC and RID.

SMA Energy Meter

• Only when two SMA Energy Meters are installed, note down the serial number and

purpose (e.g., PV production meter) in each case. This way you can identify the energy

meters in the Sunny Portal.

PV inverter

• System password

The PV system password is the same as the device password for the user group

"Installer". All devices in a PV system must be set to the same password (for user groups

and security concept, see the Sunny Explorer user manual). The default password is

1111.

• Serial number of the PV inverters

You can uniquely identify the PV inverters in Sunny Portal using the serial number.

• PV array power in kWp

This manual is related to the following products: