6  Electrical Connection

Installation Manual

CU600-1000US-IA-en-10

27

6.2 Overview of the Connection Area

6.2.1 Enclosure Openings

Figure 9: Enclosure openings of the Connection Unit

Electrical installations

All electrical installations must be made in accordance with the local electrical standards and
the National Electrical Code

®

ANSI/NFPA70 or the Canadian Electrical Code

®.

CSA C22.1.

• Use only +194°F (+90°C) copper wire for all DC wiring connections to the screw

terminals between the PV modules and the Connection Unit and between the Connection
Unit and the inverter.

• The DC input and output circuits are isolated from the enclosure and that system grounding,

if required by Section 250 of the National Electrical Code

®

, ANSI/NFPA 70, is the

responsibility of the installer.

• Make sure that no damaged cables are being used.

Item

Designation

A

Output opening in the enclosure for connecting the conduits
(diameter: 1

23

64

in. (34.5 mm) to 1

3

8

in. (34.7 mm))

B

Input opening in the enclosure with filler plugs for connecting the conduits
(diameter: 1

3

32

in. (27.8 mm) to 1

7

64

in. (28.0 mm))