6 startup, 7 servicing/cleaning, Startup – SMA CBL-DC-CMB1-10 User Manual
Page 21: Servicing/cleaning, 6startup, 7servicing/cleaning
Startup
106183_en_00
PHOENIX CONTACT
21
6
Startup
Do not start up the CBL-DC-CMB1-10 until it has been properly mounted and installed.
Make sure that all of the necessary steps described in section „Connection notes for mount-
ing and installation“ have been performed.
7
Servicing/cleaning
All electrical equipment must be kept in good condition as stipulated by the relevant stan-
dards and regulations, e.g., DIN VDE 0105-100 and accident prevention regulation BGV A3
(electrical systems and equipment).
Check the CBL-DC-CMB1-10 at regular intervals, at least once a year. The servicing inter-
val also depends on the usage and ambient conditions. Parts and components that are sub-
ject to frequent use/loads must be checked at shorter intervals. Any defects to the CBL-DC-
CMB1-10 must be eliminated as soon as they are identified. If a defective electrical system
poses an immediate danger, it must not continue to be operated.
If there is any risk of material damage or personal injury, the CBL-DC-CMB1-10 must be
stopped immediately. Before it can be started up again, the CBL-DC-CMB1-10 must be re-
turned to a safe condition. Before carrying out any servicing work with the power supply dis-
connected, observe the five basic safety rules, provided these apply to your application:
–
Disconnect safely
–
Ensure power cannot be switched on again
–
Verify safe isolation from the supply
–
Ground and short circuit
–
Cover or safeguard adjacent live parts
Document all servicing steps performed. Example information:
–
Date/serial or device number/equipment identification
–
State of the object undergoing the check
–
Activity carried out
–
Repairs/adjustments/replacement/settings, etc.
–
Skilled electrical engineer carrying out the work
DANGER: Return of the supply voltage
Make sure that switching on the input voltage cannot lead to unexpected hazardous situ-
ations.
All work on the CBL-DC-CMB1-10 must only be carried out by qualified personnel who
are familiar with the necessary safety precautions.
WARNING: Dangerous contact voltage
All servicing work must only be carried out by qualified personnel who are familiar with the
necessary safety precautions.
When carrying out regular checks and servicing work on the CBL-DC-CMB1-10, observe
the points described in the following sections in particular and also the specifications from
the corresponding standards and guidelines.