11 measure coordinate (cycle 427, din/iso: g427), Cycle run, Please note while programming – HEIDENHAIN TNC 320 (340 55x-05) Cycle programming User Manual
Page 400

400
Touch Probe Cycles: Automatic Workpiece Inspection
16.1
1
MEA
S
URE COORDINA
TE (Cy
c
le
427
, DIN/ISO: G427)
16.11 MEASURE COORDINATE
(Cycle 427, DIN/ISO: G427)
Cycle run
Touch Probe Cycle 427 finds a coordinate in a selectable axis and
saves the value in a system parameter. If you define the
corresponding tolerance values in the cycle, the TNC makes a
nominal-to-actual value comparison and saves the deviation value in
system parameters.
1
The TNC positions the touch probe at rapid traverse (value from
FMAX column) following the positioning logic (see “Executing
touch probe cycles” on page 285) to the starting point
1
. The TNC
offsets the touch probe by the safety clearance in the direction
opposite the defined traverse direction.
2
Then the TNC positions the touch probe to the entered touch point
1
in the working plane and measures the actual value in the
selected axis.
3
Finally the TNC returns the touch probe to the clearance height and
saves the measured coordinate in the following Q parameter:
Please note while programming:
X
Z
1
Parameter number
Meaning
Q160
Measured coordinate
Before a cycle definition you must have programmed a
tool call to define the touch probe axis.