HEIDENHAIN TNC 320 (340 55x-05) Cycle programming User Manual
Page 389

HEIDENHAIN TNC 320
389
16.7 MEA
S
. RECT
AN. INSIDE (Cy
c
le
423, DIN/ISO: G423)
U
Measuring log Q281: Definition of whether the TNC
is to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR423.TXT by default in the directory TNC:\.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.
U
PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
U
Tool for monitoring Q330: Definition of whether the
TNC is to monitor the tool (see “Tool monitoring” on
page 370). Input range 0 to 32767.9; alternatively, tool
name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
Example: NC blocks
5 TCH PROBE 423 MEAS. RECTAN. INSIDE
Q273=+50
;CENTER IN 1ST AXIS
Q274=+50
;CENTER IN 2ND AXIS
Q282=80
;1ST SIDE LENGTH
Q283=60
;2ND SIDE LENGTH
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+10
;CLEARANCE HEIGHT
Q301=1
;MOVE TO CLEARANCE
Q284=0
;MAX. LIMIT 1ST SIDE
Q285=0
;MIN. LIMIT 1ST SIDE
Q286=0
;MAX. LIMIT 2ND SIDE
Q287=0
;MIN. LIMIT 2ND SIDE
Q279=0
;TOLERANCE 1ST CENTER
Q280=0
;TOLERANCE 2ND CENTER
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330=0
;TOOL