HEIDENHAIN TNC 320 (340 55x-05) Cycle programming User Manual
Page 308

308
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
14.7 Compensating W
o
rk
piece Misa
lignm
ent b
y
Rota
ting the C Ax
is
(Cy
c
le
405, DIN/ISO:
G405)
U
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (= touch 
point) in the touch probe axis in which the 
measurement is to be made. Input range 
-99999.9999 to 99999.9999
U
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip. Q320 
is added to SET_UP (touch probe table). Input range 
0 to 99999.9999
U
Clearance height Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch 
probe and workpiece (fixtures) can occur. Input range 
-99999.9999 to 99999.9999
U
Traversing to clearance height Q301: Definition of
how the touch probe is to move between the 
measuring points: 
0: Move at measuring height between measuring 
points
1: Move at clearance height between measuring 
points
U
Set to zero after alignment Q337: Definition of
whether the TNC should set the display of the C axis 
to zero, or write the angular offset in column C of the 
datum table: 
0: Set display of C to 0 
>0: Write the angular misalignment, including 
algebraic sign, in the datum table. Line number = 
value of Q337. If a C-axis shift is registered in the 
datum table, the TNC adds the measured angular 
misalignment.
Example: NC blocks
5 TCH PROBE 405 ROT IN C AXIS
Q321=+50
;CENTER IN 1ST AXIS
Q322=+50
;CENTER IN 2ND AXIS
Q262=10
;NOMINAL DIAMETER
Q325=+0
;STARTING ANGLE
Q247=90
;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q337=0
;SET TO ZERO
X
Z
Q261
Q260
SET_UP(TCHPROBE.TP)
+
Q320