beautypg.com

HEIDENHAIN TNC 320 (340 55x-05) Cycle programming User Manual

Page 396

background image

396

Touch Probe Cycles: Automatic Workpiece Inspection

16.9 MEA

S

URE INSIDE WIDTH (Cy

c

le 425, DIN/ISO: G425)

U

Measuring log Q281: Definition of whether the TNC

is to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR425.TXT
by default in the directory TNC:\.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.

U

PGM stop if tolerance error Q309: Definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

U

Tool for monitoring Q330: Definition of whether the

TNC is to monitor the tool (see “Tool monitoring” on
page 370). In
put range 0 to 32767.9; alternatively, tool
name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

U

Set-up clearance Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range
0 to 99999.9999

U

Traversing to clearance height Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

Example: NC blocks

5 TCH PROBE 425 MEASURE INSIDE WIDTH

Q328=+75

;STARTNG PNT 1ST AXIS

Q329=-12.5 ;STARTNG PNT 2ND AXIS

Q310=+0

;OFFS. 2ND MEASUREMENT

Q272=1

;MEASURING AXIS

Q261=-5

;MEASURING HEIGHT

Q260=+10

;CLEARANCE HEIGHT

Q311=25

;NOMINAL LENGTH

Q288=25.05 ;MAX. LIMIT

Q289=25

;MIN. LIMIT

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL

Q320=0

;SET-UP CLEARANCE

Q301=0

;MOVE TO CLEARANCE