HEIDENHAIN TNC 320 (340 55x-05) Cycle programming User Manual
Page 324

324
Touch Probe Cycles: Automatic Datum Setting
15.4 D
A
TUM FR
OM INSIDE OF RECT
ANGLE (Cy
c
le 41
0, DIN/ISO: G41
0
)
U
Traversing to clearance height Q301: Definition of
how the touch probe is to move between the 
measuring points:
0: Move at measuring height between measuring 
points
1: Move at clearance height between measuring 
points
U
Datum number in table Q305: Enter the number in
the datum/preset table in which the TNC is to save 
the coordinates of the pocket center. If you enter 
Q305=0, the TNC automatically sets the display so 
that the new datum is at the center of the pocket. 
Input range 0 to 2999
U
New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC 
should set the pocket center. Default setting = 0. 
Input range -99999.9999 to 99999.9999
U
New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC should 
set the pocket center. Default setting = 0. Input range 
-99999.9999 to 99999.9999
U
Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the 
datum table or in the preset table:
–1: Do not use. Is entered by the TNC when old 
programs are read in (see “Saving the calculated 
datum” on page 314).
0: Write determined datum in the active datum table. 
The reference system is the active workpiece 
coordinate system.
1: Write determined datum in the preset table. The 
reference system is the machine coordinate system 
(REF system).