beautypg.com

Transferring parameters, 3 t ransf er – HEIDENHAIN SW 54843x-02 User Manual

Page 560

background image

560

Organization mode of operation

8.3 T

ransf

er

Transferring parameters

Parameters are backed up in two steps:

Creating a parameter backup: The parameters are archived in ZIP
files and stored in the control.

Transmitting/Receiving the parameter backup files.

Restoring parameters: Restores the backup files into the active
data on the MANUALplus (login required).

Parameter selection

You can also create a parameter backup without connecting to an
external storage device.

Press the Transfer soft key (login required).

Open the parameter transfer.

Parameter backup data

A parameter backup file contains all the parameters and tables of the
MANUALplus except tool and technology data.

Path and file names of the backup files:

Config data: \para\PA_*.zip

Tables: \table\TA_*.zip

The transfer window only shows the "para" folder. The associated file
in the "table" folder is automatically created and transferred.

Press the Transmit or Receive soft key to start transferring the files.

Soft keys for parameter transfer

Transmits all marked files from the
control to the remote station.

Receives all files marked on the
remote station.

Deletes all marked files after a
confirmation prompt (login required).

Creates a parameter backup data
record as a .zip file.

Restores data from the selected
backup data record to the active
control system (login required).

Marks all files in the current window.

Marks or unmarks the file at the
cursor position and moves the cursor
down one position.