beautypg.com

Switching inputs and outputs ext (x41) – HEIDENHAIN ND 231 B v.1 User Manual

Page 35

background image

35

Switching Inputs and Outputs EXT (X41)

Inputs

Input signals

Internal pull-up resistor 1 k

, active with low level

Trigger by making contact against 0 V or
by low level signal over TTL logic device

Delay for set/zero reset: t

d

2 ms

Minimum pulse duration for all signals: t

min

30 ms

Signal level of inputs

Status

Level

High

+ 3.9 V

U

+ 15 V

Low

– 0.5 V

U

+ 0.9 V; I

6 mA

B

UCE

E

C

Pin 1.10

0 V

+ UB

32 V

I

100 mA

t

min

30 ms

0V

E

0V

E

t

min

Outputs

Output signals

Open collector outputs, active with low level

Delay until signal output: t

d

30 ms

Signal duration of zero signal, trigger limit A1, A2: t

0

180 ms

Signal level of outputs

Status

Level

High

U

+ 32 V; I

10 µA

Low

U

+ 0.4 V; I

100 mA