Elation Professional 575E User Manual
Page 40

Design Spot 575E™
©Elation Professional® 40
Design Spot 575E™
Channel 23 - Speed pan/tilt movement:
0-225
Max to min speed
226-235
Blackout by movement
236-245
Blackout by all wheel changing
246-255 No
function
Channel 24 - Lamp on/off, reset, internal programs:
0-19
Color change normal
20-39
Color change to any position
40-59 Lamp
on
60-79
Lamp switch off
80-84
All motor reset
85-87 Scan
motor
reset
88-90
Colors motor reset
91-93
Gobo motor reset
94-96
Shutter & Dimmer motor reset
97-99 Other
motor
reset
100-119
Internal program 1 (secne1~8 of EPROM)
120-139
Internal program 2 (secne9~16 of EPROM)
140-159
Internal program 3 (secne17~24 of EPROM)
160-179
Internal program 4 (secne25~32 of EPROM)
180-199
Internal program 5 (secne33~40 of EPROM)
200-219
Internal program 6 (secne41~48 of EPROM)
220-239
Internal program 7 (secne49~56 of EPROM)
240-255
Music Control (scene of Program 1)