beautypg.com

Elation Professional 575E User Manual

Page 29

background image



Design Spot 575E™

©Elation Professional® 29

Design Spot 575E™

and channel 3 to "164" (256+164=420).

4. Wait for approximately 20 seconds for the unit to complete the

address reset function.

B. Run if no DMX – This function dictates how the fixture will function if it

looses DMX signal during normal operation. The default function is set to

hold, in which the fixture will lock into the last DMX signal it received and

remain in that position until it is turned off or begins receiving a new DMX

signal. If the fixture is turned on without any DMX signal, the fixture will

automatically go in to sound-active mode. Available settings are: “Close” –

Shutter flags will close. “Hold” – Fixture will remain at it’s last settings. “Auto”

– Fixture will go into stand-alone mode, running the built-in program. “Music”

– The fixture will go into sound-active mode.

C. Pan Reverse - This function allows you to invert all pan movements. Use

the Up and Down buttons to turn this function On and Off. Press the Enter

button to accept the change or the Mode button to cancel and return to the

main menu.

D. Tilt Reverse - This function allows you to invert all tilt movements. Use the

Up and Down buttons to turn this function On and Off. Press the Enter

button to accept the change or the Mode button to cancel and return to the

main menu.

E. Fine resolution – This function changes the DMX channel operation from

8bit to 16bit.

F. Pan Degree – This function changes the maximum Pan resolution from

either 540˚ or 630˚. The default function is 540˚.

G. Feedback – This function turns the feedback correction on or off. This

function is set to on as default.