Design Spot 575E™

©Elation Professional® 28

Design Spot 575E™

automatically switch the lamp off. Turn the LCD controls to select the maximum inside

temperature between 80° C and 139° C. Inside temperatures below 90° C are not critical.

90° C and more should lead to the lamp being switched off. Please note that the outside

temperature should not exceed 45° C.

PERSONALITY:

1. Status

setting

A. Address via DMX - This function allows the DMX address to remotely be

adjusted from a DMX console. This setting requires special settings for both the

controller and the fixture. RDMX is on by default. Follow the procedure listed

below to access the RDMX functions:

Fixture Settings:

1. Access the main menu.

2. Tap the UP button until “Address via DMX” is displayed, press ENTER.

3. Tap the UP button until “RDMX” is displayed, press ENTER.

4. The display will show “ON/OFF.”

5. Press the UP button to display “ON” to activate this function, or “OFF” to

deactivate this function.

6. Press ENTER to confirm.

7. Press MODE/ESC to return to the main menu.

Controller Settings:

1. Set the DMX value of channel 1 to a value of 7.

2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is

set to "7" you can adjust the starting address between 1 and 255. When

set to "8" you can adjust the starting address between 256 and 511.

3. Use channel 3 to set your desired DMX starting address. For example: If

you want to set the starting address to 57, set channel 1 to a value of “7,”

set channel 2 to a value of “7” and use channel 3 to set your address to

57 by selecting a channel value of 57. Example 2: If you want to set the

starting address to 420, set channel 1 to a value of “7,” channel 2 to "8"