Maintenance, Diagnostic display code definitions, Diagnostic codes – Polaris 2016 600 Rush PRO-S User Manual
Page 105
103
MAINTENANCE
Diagnostic Display Code Definitions
Diagnostic Codes
Component
Condition
SPN
FMI
Knock Level Cylinder 1 (MAG)
Maximum Detonation Correction
Limit Reached
1352
0
Knock Above Critical Level
16
Knock Level Cylinder 2 (PTO)
Maximum Detonation Correction
Limit Reached
1353
0
Knock Above Critical Level
16
Sensor Supply Voltage 1
(TPS/TMAP Sensor Power)
Voltage Too Low
3509
4
Sensor Supply Voltage 2
(Ground Speed Sensor)
Voltage Too Low
3510
4
ECU Output Supply Voltage 2
(Injection Supply PWR)
Voltage Too High
3598
3
Voltage Too Low
4
Throttle Release Signal
Voltage Too High
520194
3
Voltage Too Low
4
Throttle Stuck
7
Chassis Relay
Driver Circuit Open/Grounded
520208
5
Driver Circuit Short to B+
3
Exhaust Valve Solenoid
(600 Only)
Driver Circuit Grounded
520215
5
Driver Circuit Short to B+
3
EV Actuator Driver (Controller)
(800 H.O. Only)
Voltage Too High
520324
3
Voltage Too Low
4
Learn Failure
13
Hardware Failure
12
Commanded Pos. Not Achieved
7
PWM Set Missing
2
MAX Temperature Exceeded
520334
31
Signal Out of Range - Valve Open
520325
31
Signal Out of Range - Valve Mid
520326
31
Signal Out of Range - Valve Closed
520327
31
Short to Battery Voltage
520335
3
Short to Ground
4
Abnormal Transition
10
Electronic Oil Pump
Driver Circuit Open / Grounded
3589
4
Driver Circuit Grounded
5
Oil Pump or Fuel Injector
Settings not Programmed
Out of Calibration
520241
13