MAINTENANCE

Diagnostic Display Code Definitions

Diagnostic Codes

Component

Condition

SPN

FMI

Knock Level Cylinder 1 (MAG)

Maximum Detonation Correction
Limit Reached

1352

0

Knock Above Critical Level

16

Knock Level Cylinder 2 (PTO)

Maximum Detonation Correction
Limit Reached

1353

0

Knock Above Critical Level

16

Sensor Supply Voltage 1
(TPS/TMAP Sensor Power)

Voltage Too Low

3509

4

Sensor Supply Voltage 2
(Ground Speed Sensor)

Voltage Too Low

3510

4

ECU Output Supply Voltage 2
(Injection Supply PWR)

Voltage Too High

3598

3

Voltage Too Low

4

Throttle Release Signal

Voltage Too High

520194

3

Voltage Too Low

4

Throttle Stuck

7

Chassis Relay

Driver Circuit Open/Grounded

520208

5

Driver Circuit Short to B+

3

Exhaust Valve Solenoid
(600 Only)

Driver Circuit Grounded

520215

5

Driver Circuit Short to B+

3

EV Actuator Driver (Controller)
(800 H.O. Only)

Voltage Too High

520324

3

Voltage Too Low

4

Learn Failure

13

Hardware Failure

12

Commanded Pos. Not Achieved

7

PWM Set Missing

2

MAX Temperature Exceeded

520334

31

Signal Out of Range - Valve Open

520325

31

Signal Out of Range - Valve Mid

520326

31

Signal Out of Range - Valve Closed

520327

31

Short to Battery Voltage

520335

3

Short to Ground

4

Abnormal Transition

10

Electronic Oil Pump

Driver Circuit Open / Grounded

3589

4

Driver Circuit Grounded

5

Oil Pump or Fuel Injector
Settings not Programmed

Out of Calibration

520241

13